Adjustment Programm for SCENICVIEW X17-2 ======================================== 1. Introduction Analog flat screen monitors such as the X17-2 must be adapted to the screen controller for each used screen resolution and refresh rate. The program LCDADJ.EXE generates the test pattern required for precise calibration. 2. Preparation Select the screen mode to adjust (e.g. under Windows 9x via Start - Settings - Control Panel - Display - Settings). Further information is provided in the operating manual of the monitor. Allow the unit to warm up for approx.. 20 minutes prior to calibration. 3. Installation of the driver Plug & Play operating systems (Windows 9x / ME / 2000 and XP) ask for a driver after connecting the flat screen monitor to the PC and reboot. Please follow the instructions of the operating system. On other operating systems please select the screen mode manually. The optimal resolution for this screen is 1280x1024 and the optimal refresh rate is 60Hz. 4. Calibration Start the program LCDADJ.EXE. The auto adjustment could be performed by the AUTO button. In most cases the result of the auto adjustment is OK. It is also recommended that the OSD function AUTO LEVEL is performed in order to achive the optimum contrast setting. In seldom cases it is necessary to optimize the image manually and sometimes a vertical refresh rate higher than 60 Hz would improve the picture. 5. Any problem or other question you need clarified? Please contact one of our IT Service Shops or your local sales partner or office for advice.